Model | CS-151F1 | CS-152F1 | CS-150F1 |
---|---|---|---|
Target of measurement |
SC-1 (ammonia/hydrogen peroxide aqueous solution) |
SC-2 (hydrochloric acid/hydrogen peroxide aqueous solution) |
SPM (sulfuric acid/hydrogen peroxide aqueous solution) |
Multi-monitoring with one unit of up to 4 types of chemical solutions or ranges possible. | |||
Measurement principle | Absorption spectrometry | ||
Concentration computation principle |
Temperature-compensated multivariate analysis | ||
Measurement range (mass %) |
NH3: 0.00% to 1.00% H2O2: 0.00% to 5.00% H2O: 94.0% to 100.0% |
HCI: 0.00% to 2.00% H2O2: 0.00% to 2.00% H2O: 96.0% to 100.0% |
H2SO4: 70.0% to 96.0% H2O2: 0.00% to 10.00% H2O: 4.0% to 30.0% |
Repeatability (mass %) (within ±1% room temperature) |
NH3: ±0.15% H2O2: ±0.30% H2O: ±1.5% |
HCI: ±0.15% H2O2: ±0.15 % H2O: ±1.5% |
H2SO4: ±0.50% H2O2: ±0.50% H2O: ±1.5% |
?Repeatability for the list above is for the cell unit type.Please contact us for the repeatability of the in-line cell type. ?Differences in the above list may occur depending on measurement range.(Please see our website for details.) |
|||
Sample solution temperature | 20 to 80: (when using Inline cell) 20 to 30: (when using cell unit) | ||
Measurement cycle | Approx. 3 seconds | ||
Content of LCD and input |
? 1st component: measured concentration value (%) ?Error code ? 2nd component: measured concentration value (%) ?Parallel concentration alarm output invalid status ? 3rd component: measured concentration value (%) ?Serial/parallel status ? 1st and 2nd components: concentration alarm status ?Background compensation data |
||
RS-232C serial input |
? Serial/parallel status switching ?Parallel concentration alarm output status ? Measurement data transfer request (valid/invalid) ? 1st and 2nd component concentration alarm setting ??Target measurement solution switching |
||
Parallel input |
12 to 30 V DC (photocoupler insulated) ? Parallel concentration alarm output ? Target measurement solution switching ? Background compensation |
||
Parallel output |
Open collector output (photocoupler insulated) ?? 1st component concentration alarm, 4 types Max. current when on: ? ? 2nd component concentration alarm, 4 types DC 5 mA (no internal protection resistor) ? Device error Max. impressed voltage when off: 30 V DC ? Measuring ? Target measurement solution type ? Background compensation status |
||
Solution temperature input |
Terminal block connection (M3 terminal screws) ? Platinum resistance temperature sensor: Pt100 (Pt100 sensor should be prepared by customers) |
||
Analog output |
? 1st component concentration alarm, 4 types: 4 to 20 mA ? 2nd component concentration alarm, 4 types: 4 to 20 mA ?We also support other measurement ranges. Please specify when ordering. |
||
Fiber optic cable | Dedicated CS-100F1 Series fiber optic cable (25 ±15: installation temperature) | ||
Sample cell | We can supply dedicated sample cells (inline cell or cell unit) for various kinds of chemical solutions. | ||
Power supply | 100 V to 230 V AC (single phase) ±10%, 50/60 Hz, approx. 100 VA | ||
Dimensions | 205 (W) x 329 (D) x 269 (H) mm 8.1 (W) x 13.0 (D) x 10.6 (H) in (excluding protruding part) | ||
Weight | Approx. 11 kg |
Note: Please consult us regarding concentration monitors for chemical solutions other than those given above.
Schematics
Concentration monitor
Inline cell Cell unit